Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 168
Filter
1.
Rev. bras. ortop ; 58(2): 265-270, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449785

ABSTRACT

Abstract Objective To evaluate the postoperative functional and radiographic outcomes of the shoulder of patients submitted to transosseous suturing of a greater tuberosity fracture (GTF) through an anterolateral route and the influence of the glenohumeral dislocation on these outcomes. Methods We conducted a retrospective study and functional assessment using the Constant-Murley score. The distance between the greater tuberosity and the joint surface of the proximal humerus (in true anteroposterior radiographs) after the union was calculated. We used the Fisher exact test for the categorical independent variables, and the Student t or Mann-Whitney test for the non-categorical variables. Results In total, 26 patients met the inclusion criteria, and 38% of the sample presented an association between glenohumeral dislocation and GTF. The mean Constant-Murley score was of 82.5 + 8.02 points. The presence of an associated dislocation did not alter the functional outcome. The mean distance between the greater tuberosity of the humerus and the joint surface of the humeral head after the union was of 9 + 4.3 mm below the articular line of the humeral head. The dislocation led to a lower level of reduction, but this did not influence the Constant-Murley score. Conclusion The cases of GTF submitted to surgical treatment with transosseous sutures had good functional outcomes. The presence of dislocation made the anatomical reduction of the greater tuberosity difficult. However, it did not influence the Constant-Murley score.


Resumo Objetivo Avaliar os resultados funcional e radiográfico pós-operatórios do ombro, em pacientes submetidos a sutura transóssea de fratura da tuberosidade maior (FTM) por acesso anterolateral, e a influência da luxação glenoumeral nesses resultados. Métodos Realizou-se estudo retrospectivo e avaliação funcional (pela escala de Constant-Murley). Calculou-se a distância entre a tuberosidade maior e a superfície articular do úmero proximal (por meio de radiografia em incidência anteroposterior verdadeira) após a consolidação. Usou-se o teste Exato de Fisher para as variáveis independentes categóricas, e os testes tde Student ou de Mann-Whitney para as não categóricas. Resultados Ao todo, 26 pacientes preencheram os critérios de inclusão. A associação de luxação glenoumeral com FTM foi observada em 38% da amostra. A média da pontuação na escala de Constant-Murley foi de 82,5 + 8,02. A presença de luxação associada não alterou o resultado funcional. A distância média da consolidação da tuberosidade maior do úmero em relação à superfície articular da cabeça umeral foi de 9 + 4,3 mm abaixo da linha articular da cabeça umeral. Pacientes com luxação associada evoluíram com redução menor, mas isso não influenciou na pontuação na escala de Constant-Murley. Conclusão As FTMs submetidas ao tratamento cirúrgico com sutura transóssea evoluíram com bom resultado funcional. A presença de luxação dificultou a redução anatômica da tuberosidade maior. Entretanto, isso não influenciou na pontuação na escala de Constant-Murley.


Subject(s)
Humans , Shoulder Dislocation/surgery , Suture Techniques , Suture Anchors , Humeral Fractures/surgery
2.
Chinese Journal of Medical Instrumentation ; (6): 247-251, 2023.
Article in Chinese | WPRIM | ID: wpr-982222

ABSTRACT

OBJECTIVE@#To study the mechanical properties related to the typical functional failure modes of non-absorbable suture anchor in clinical use, and to support product design, development and verification.@*METHODS@#By retrieving the database of relevant adverse events, the typical functional failure modes of non-absorbable suture anchor were summarized, and the influencing factors of functional failure were further analyzed by studying the mechanical properties related to functional failure. The publicly available test data was retrieved for verification and provided reference for the researchers.@*RESULTS@#The typical functional failure modes of non-absorbable suture anchor include anchor failure, suture failure, fix loosening, inserter failure, which are related to the mechanical properties of products, such as screw-in torque and break torque of screw-in anchors, insertion force of knock-in anchors, suture strength, pull-out force before and after system fatigue test and elongation of sutures after fatigue test.@*CONCLUSIONS@#Enterprises should pay attention to improving the mechanical performance level of products through material, structural design and the suture weaving process to ensure the safety and effectiveness of products.


Subject(s)
Suture Anchors , Suture Techniques , Sutures , Absorbable Implants , Biomechanical Phenomena , Materials Testing
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 675-680, 2023.
Article in Chinese | WPRIM | ID: wpr-981651

ABSTRACT

OBJECTIVE@#To investigate effectiveness of suture anchor fixation combined with Nice knot strapping via longitudinal patellar drilling in the treatment of patellar inferior pole fractures.@*METHODS@#A clinical data of 37 patients with unilateral patellar inferior pole fracture who met the selection criteria between June 2017 and June 2021 was retrospectively analyzed. Among them, 17 cases were treated with the suture anchor fixation combined with Nice knot strapping via longitudinal patellar drilling (group A), and 20 cases were treated with the traditional Kirschner wire tension band technique (group B). There was no significant difference in terms of gender, age, body mass index, fracture side, combined medical disease, and preoperative hemoglobin between the two groups ( P>0.05). Operation time, intraoperative blood loss, postoperative complications, fracture healing time, knee range of motion, and knee function Bostman score (range of motion, pain, daily work, muscle atrophy, walking aids, knee effusion, soft leg, and stair climbing) and grading were recorded in both groups at last follow-up.@*RESULTS@#There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). All incisions healed by first intention. All patients were followed up 1-2 years, with an average of 1.7 years. X-ray films reexamination showed that all fractures in group A healed, while 2 cases in group B did not heal. There was no significant difference in bone healing time between the two groups ( P>0.05). At last follow-up, the knee range of motion, the range of motion score of Bostman score, total score and effectiveness grading in group A were significantly better than those in group B ( P<0.05). There was no significant difference in the other items of Bostman scores between the two groups ( P>0.05). During follow-up, 2 cases of internal fixation failure and 1 case of internal fixator irritation occurred in group B, and no complication related to internal fixation occurred in group A. The occurrence of complications was significantly lower in group A than in group B ( P<0.05).@*CONCLUSION@#Compared with the traditional Kirschner wire tension band technique, the suture anchor combined with Nice knot strapping via longitudinal patellar drilling for the patellar inferior pole fractures has the advantages of simple operation, reliable fixation, early flexion and extension activity, and better functional recovery of knee joint.


Subject(s)
Humans , Male , Female , Blood Loss, Surgical , Bone Wires , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Knee Injuries , Patella/surgery , Retrospective Studies , Suture Anchors , Treatment Outcome
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 572-577, 2023.
Article in Chinese | WPRIM | ID: wpr-981634

ABSTRACT

OBJECTIVE@#To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.@*METHODS@#The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.@*RESULTS@#There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).@*CONCLUSION@#For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.


Subject(s)
Humans , Posterior Cruciate Ligament/injuries , Suture Anchors , Fractures, Avulsion/surgery , Retrospective Studies , Tibial Fractures/surgery , Arthroscopy/methods , Fracture Fixation, Internal/methods , Knee Joint/surgery , Bone Screws , Suture Techniques , Treatment Outcome
5.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 538-544, 2023.
Article in Chinese | WPRIM | ID: wpr-981628

ABSTRACT

OBJECTIVE@#To explore the effectiveness and advantages of using Fastpass Scorpion suture passer to stitch the inferior capsulolabral complex in arthroscopic Bankart repair compared with traditional arthroscopic suture shuttle.@*METHODS@#The clinical data of 41 patients with Bankart lesion, who met the selection criteria and were admitted between August 2019 and October 2021, was retrospectively analyzed. Under arthroscopy, the inferior capsulolabral complex was stitched with Fastpass Scorpion suture passer in 27 patients (FS group) and with arthroscopic suture shuttle in 14 patients (ASS group). There was no significant difference between the two groups ( P>0.05) in gender, age, injured side, frequency of shoulder dislocation, time from first dislocation to operation, and preoperative Rowe score of shoulder. Taking successful suture and pull-tightening as the criteria for completion of repair, the number of patients that were repaired at 5∶00 to 6∶00 (<6:00) and 6∶00 to 7∶00 positions of the glenoid in the two groups was compared. The operation time, and the difference of Rowe shoulder score betwee pre- and post-operation, the occurrence of shoulder joint dislocation, the results of apprehension test, and the constituent ratio of recovery to the pre-injury movement level between the two groups at 1 year after operation.@*RESULTS@#Both groups completed the repair at 5∶00 to 6∶00 (<6∶00), and the constituent ratio of patients completed at 6∶00 to 7∶00 was significantly greater in the FS group than in the ASS group ( P<0.05). The operation time was significantly shorter in the FS group than in the ASS group ( P<0.05). All incisions in the two groups healed by first intention. All patients were followed up 12-36 months (mean, 19.1 months). No anchor displacement or neurovascular injury occurred during follow-up. Rowe score of shoulder in the two groups significantly improved at 1 year after operation than preoperative scores ( P<0.05), and there was no significant difference in the difference of Rowe shoulder score between pre- and post-operation between the two groups ( P>0.05). At 1 year after operation, no re-dislocation occurred, and there was no significant difference in the apprehension test and the constituent ratio of recovery to the pre-injury movement level between the two groups ( P>0.05).@*CONCLUSION@#Compared with the arthroscopic suture shuttle, using Fastpass Scorpion suture passer to stitch the inferior capsulolabral complex in arthroscopic Bankart repair is more convenient, saves operation time, and has good effectiveness.


Subject(s)
Humans , Animals , Arthroscopy/methods , Scorpions , Retrospective Studies , Treatment Outcome , Shoulder Dislocation/surgery , Sutures , Equidae , Shoulder Joint/surgery , Joint Instability/surgery , Suture Anchors , Recurrence , Range of Motion, Articular
6.
Odovtos (En línea) ; 24(1)abr. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1386569

ABSTRACT

Abstract Immediate loading of full-arch prostheses on dental implants in the upper arch is challenging, as the bone is of low quality and obtaining sufficient torque may be difficult. The purpose of this case report is to describe the rehabilitation of a full- arch by means of placement of four internal tapered connection tilted implants and immediate loading. A 65-year-old man sought dental care with a partially edentulous upper arch. The teeth presented mobility and were extracted. In a second step, two conventional-length implants were placed in the anterior region and two tilted and nasal wall-directed extra-long implants in the posterior region. The insertion torques of 60 N.cm allowed the installation of an immediate prosthesis (hybrid). The clinical case report suggests that the placement of tilted and extra-long implants in the paranasal bone and immediate loading may be a viable option for rehabilitation of the edentulous upper arch.


Resumen La carga inmediata de prótesis de arco completo en implantes dentales en el arco superior es un desafío, ya que el hueso es de baja calidad y puede ser difícil obtener un par suficiente. El propósito de este reporte de un caso es describir la rehabilitación de un arco completo mediante la colocación de cuatro implantes inclinados de conexión cónica interna y carga inmediata. Un hombre de 65 años buscó atención dental con un arco superior parcial sin dientes. Los dientes presentaron movilidad y fueron extraídos. En un segundo paso, se colocaron dos implantes de longitud convencional en la región anterior y dos implantes extralargos inclinados y dirigidos a la pared nasal en la región posterior. Los pares de inserción de 60 N.cm permitieron la instalación de una prótesis inmediata (híbrida). El informe del caso clínico sugiere que la colocación de implantes inclinados y extralargos en el hueso paranasal y la carga inmediata pueden ser una opción viable para la rehabilitación del arco superior desdentado.


Subject(s)
Humans , Male , Aged , Dental Implants , Suture Anchors
7.
Artrosc. (B. Aires) ; 29(4): 178-184, 2022.
Article in Spanish | LILACS, BINACIS | ID: biblio-1411049

ABSTRACT

Introducción: las fracturas de la eminencia intercondílea son fracturas por avulsión del ligamento cruzado anterior (LCA). Las opciones terapéuticas en las fracturas desplazadas consisten en un abordaje artroscópico y fijación de las fracturas. Actualmente se debate sobre la técnica quirúrgica y el material de fijación. El objetivo de nuestra revisión bibliográfica es analizar los diferentes métodos de fijación artroscópica disponibles en la actualidad para el tratamiento de las fracturas de la eminencia intercondílea. Materiales y métodos: se realizó una revisión sistemática de la bibliografía con el formato PRISMA. Se incluyeron fracturas de la eminencia intercondílea en adultos tratados mediante artroscopía. Resultados: se analizaron dieciséis artículos, con un total de quinientas cincuenta y una fracturas. El método de fijación más utilizado fue la sutura (31%), cerclaje (25%), anclas (22%), fijación con Kw (8%), Endobutton® (6.3%), tornillos (4.5%) y alambre (3%). Conclusión: ningún método de fijación demostró superioridad en cuanto a porcentajes de estabilidad, consolidación y tiempo de inmovilización. Nivel de Evidencia: II


Introduction: fractures of the intercondylar eminence are avulsion fractures of the anterior cruciate ligament (ACL). Treatment options for displaced fractures consist of an arthroscopic approach and fracture fixation. There is currently debate about the surgical technique and the fixation material. The aim of our literature review is to analyze the different methods of arthroscopic fixation currently available in the treatment of fractures of the intercondylar eminence.Materials and methods: a systematic review of the bibliography was carried out using the PRISMA format. The inclusion criteria were fractures of the intercondylar eminence in adults treated by arthroscopy.Results: sixteen articles were analyzed, with a total of 551 fractures. The most affected knee was the right with 66% of cases. The most used fixation method was suture (31%), cerclage (25%), anchors (22%), Kw fixation (8%), Endobutton® (6.3%), screws (4.5%) and wire (3%).Conclusions: no fixation method showed the superiority in terms of percentages of stability, consolidation, and immobilization time. Level of Evidence: III


Subject(s)
Humans , Adult , Arthroscopy/methods , Tibial Fractures/surgery , Fracture Fixation, Internal/methods , Sutures , Bone Screws , Bone Wires , Suture Anchors
8.
Braz. dent. sci ; 25(3): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1378432

ABSTRACT

Objetivo: O objetivo deste estudo é avaliar sistematicamente as evidências disponíveis para recidiva do tratamento da mordida aberta esquelética usando dispositivos de ancoragem temporária e cirurgia ortognática. Material e Métodos: Cinco bases de dados eletrônicas como MEDLINE, COCHRANE, SCIELO, GOOGLE SCHOLAR, EMBASE foram pesquisadas sistematicamente até junho de 2020. Os estudos de qualidade metodológica foram classificados por meio da Ferramenta de Avaliação de Qualidade do Projeto de Práticas de Saúde Pública Eficazes (EPHPP). Resultados: No total, 1.005 estudos foram identificados para triagem e 6 estudos foram elegíveis. O instrumento de avaliação da qualidade apresentou qualidade moderada para todos os estudos. A correção imediata pós-tratamento da mordida aberta foi melhor nos estudos cirúrgicos do que nos estudos tratados com TADs. Conclusão: A estabilidade dos resultados do tratamento da mordida aberta anterior foi comparável nos casos tratados em ambas as modalidades de tratamento. A recidiva da mordida aberta anterior foi associada a casos em que a sobremordida pós-tratamento foi mínima. A sobremordida parece ser mais estável quando apenas a maxila foi operada do que com cirurgias bimaxilares. A rotação anti-horária da mandíbula com subsequente redução da altura facial anterior foi melhor na correção cirúrgica do que através de TADs (AU)


Objective: The purpose of this study is to systematically assess the available evidence for relapse of skeletal open bite treatment using temporary anchorage devices and orthognathic surgery. Materials and Methods: Five electronic databases such as MEDLINE, COCHRANE, SCIELO, GOOGLE SCHOLAR, EMBASE were systematically searched up to June 2020. Methodological quality studies were graded by means of the Effective Public Health Practice Project (EPHPP) Quality Assessment Tool. Results: In total, 1005 studies were identified for screening, and 6 studies were eligible. The quality assessment tool showed moderate quality for all the studies. The immediate post treatment correction of open bite was better in the surgical studies than in the studies treated with TADs. Conclusion: Stability of treatment results of anterior openbite was comparable in cases treated in both the treatment modalities. Relapse of anterior open bite was associated with cases in which the posttreatment overbite was minimal. Overbite seems to be more stable when only the maxilla has been operated on than with bi-maxillary surgeries. Counterclockwise rotation of the mandible with subsequent reduction of anterior facial height was better in surgical correction than through TADs. (AU)


Subject(s)
Surgery, Oral , Open Bite , Suture Anchors , Orthognathic Surgery
9.
Chinese Journal of Traumatology ; (6): 49-53, 2022.
Article in English | WPRIM | ID: wpr-928483

ABSTRACT

PURPOSE@#The main aim is to provide clinical reference for the application of mini suture anchor in the reduction and fixation of displaced temporomandibular joint (TMJ) disc with intracapsular condylar fracture.@*METHODS@#From October 2018 to October 2019, 21 patients (31 sides) with intracapsular condylar fractures and articular disc displacement from West China Hospital of Stomatology, Sichuan University were included. The selection criteria were: (1) mandibular condylar fractures accompanied by displacement of the TMJ disc, confirmed by clinical examination, CT scan and other auxiliary examinations; (2) indication for surgical treatment; (3) no surgical contraindications; (4) no previous history of surgery in the operative area; (5) no facial nerve injury before the surgery; (6) informed consent to participate in the research program and (7) complete data. Patients without surgical treatment were excluded. The employed patients were followed up at 1, 3, 6 and 12 months after operation. Outcomes were assessed by success rate of operation, TMJ function and radiological examination results at 3 months after operation. Data were expressed as number and percent and analyzed using SPSS 19.0.@*RESULTS@#All the surgical procedures were completed successfully and all the articular discs were firmly attached to the condyles. The articular disc sufficiently covered the condylar head after the fixation. The fixation remained stable when the mandible was moved in each direction by the surgeons. No complications occurred. The functions of the TMJ were well-recovered postoperatively in most cases. CT scan revealed that the screws were completely embedded in the bone without loosening or displacement.@*CONCLUSION@#Mini suture anchor can provide satisfactory stabilization for the reduced articular disc and also promote the recovery of TMJ functions.


Subject(s)
Humans , Joint Dislocations/surgery , Mandible , Mandibular Condyle , Mandibular Fractures/surgery , Suture Anchors , Temporomandibular Joint Disc/surgery
10.
China Journal of Orthopaedics and Traumatology ; (12): 679-683, 2021.
Article in Chinese | WPRIM | ID: wpr-888338

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of distal radius T-plate combined with suture anchor and distal clavicle anatomical locking plate combined with suture anchor in the treatment of Neer Ⅱb distal clavicle fracture.@*METHODS@#From June 2014 to June 2018, 42 patients with Neer Ⅱb distal clavicle fractures were retrospectively analyzed. According to different surgical methods, they were divided into the observation group (T-shaped plate combined with suture anchor) and the control group (anatomical locking plate combined with suture anchor). There were 22 patients in the observation group and 20 patients in the control group. In the observation group, there were 13 males and 9 females, aged from 22 to 70 (45.78± 14.44) years old, 12 cases on the left side and 10 cases on the right side, 8 cases of traffic accident injury and 14 cases of fall. In the control group, there were 12 males and 8 females, aged from 24 to 66 (44.17±15.58) years, 13 cases on the left side and 7 cases on the right side, 6 cases of traffic accident injuryand 14 cases of fall. The operation time, intraoperative blood loss and fracture healing time were compared between the two groups, and Constant Murley score was used to evaluate shoulder joint function.@*RESULTS@#The patients in both groups were followed up for 18 to 24 (20.96±2.02) months. The incisions of both groups were healed at stageⅠ. The fracture ends of both groups were bony healed at the last follow up. There was no significant difference in operation time, intraoperative blood loss and fracture healing time between two groups (@*CONCLUSION@#The two methods can obtain satisfactory results in the treatment of Neer Ⅱb distal clavicle fractures, especially suitable for patients with comminuted distal clavicle fractures or osteoporosis; the clinical effect of the treatment of NeerⅡb distal clavicle fractures with T type distal radius plate combined with suture anchor is satisfactory, which provides another feasible treatment scheme for clinic.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Bone Plates , Case-Control Studies , Clavicle/surgery , Fracture Fixation, Internal , Fractures, Bone/surgery , Retrospective Studies , Suture Anchors , Treatment Outcome
11.
China Journal of Orthopaedics and Traumatology ; (12): 544-549, 2021.
Article in Chinese | WPRIM | ID: wpr-888312

ABSTRACT

OBJECTIVE@#To compare and analyze the mechanical differences between single-row suture anchor fixation for repairing rotator cuff injuries and double-row suture bridges for repairing rotator cuff injuries from a biomechanical perspective.@*METHODS@#The CT scan data of healthy adult shoulder joint were imported into Mimics, Geomagics and Hypermesh to carry out reverse reconstruction of two repair models, material assignment and mesh division, and the tearing of supraspinatus muscle was designed. After treatments, the load and boundary conditions were applied to the shoulder joint in ABAQUS software. The shoulder joint was fixed with four working conditions including flexion 15 °, flexion 30 °, internal rotation 15 ° and internal rotation 30 ° after anchor fixationand repair. The stress changes of the upper rotator cuff muscle and the anchor with thread were compared under these four conditions.@*RESULTS@#Under the two flexion conditions, the stress of the supraspinatus in the double row suture bridge fixation model was 8.3% and 12% less than that in the single-row suture anchor fixation, respectively. Under the two internal rotation conditions, the stress of supraspinatus in the double row suture bridge fixation model was 47% and 48% less than that in the single row fixation repair model, respectively.@*CONCLUSION@#The "load sharing" effect between the two rows of four anchors makes the stress distribution more dispersed, increases the contact area between the supraspinatus muscle and the humerus, reduces the stress of the anchor, avoids the serious stress concentration phenomenon, and explains the advantages of the fixation method of the double row suture bridge from the biomechanical angle.


Subject(s)
Adult , Humans , Biomechanical Phenomena , Cadaver , Rotator Cuff Injuries/surgery , Suture Anchors , Suture Techniques , Sutures
12.
China Journal of Orthopaedics and Traumatology ; (12): 160-164, 2021.
Article in Chinese | WPRIM | ID: wpr-879390

ABSTRACT

Shoulder arthroscopic as a conventional method usually is applied to repair rotator cuff tears. In clinical, plenty single-row, double-row and transosseous tunnels suture technique are performed, but the ideal suture technique for rotator cuff repair is not found. Compared with single-row, double-row has better strength in biomechanics property. As the two best suture technique among the single-row, massive cuff stitch and modified Mason-Allen suture have the strongest biomechanics property. Clinical trials indicate that double-row could improve healing rates, but there are no significant difference in clinical outcome functional scores. Transosseous tunnel techniques possess a better bio-mechanic property, which could improve regional micro-environment and induce tendon-bone healing. Transosseous tunnel techniques are better for small to media size rotator cuff tears and osteoporosis patient. The author suggest that optimal rotator cuff repair technique should performed according to skill of performer and individual of patient by analysing bio-mechanic properties, clinical outcome, operative complexity and patient situation. The technique should follow simple opertaion, rapid, less trauma, stable fixation and utility to perform.


Subject(s)
Humans , Arthroscopy , Rotator Cuff/surgery , Rotator Cuff Injuries/surgery , Suture Anchors , Suture Techniques , Sutures
13.
Int. j. odontostomatol. (Print) ; 14(1): 136-146, mar. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1056513

ABSTRACT

RESUMEN: En ortodoncia, las miniplacas se utilizan como dispositivo de anclaje temporal (TAD) para la realización de movimientos dentales que permiten el uso de fuerzas ortopédicas en ellos. En comparación con los mini tornillos, las miniplacas tienen la ventaja de una tasa de falla muy baja, pero la desventaja es que para la extracción se necesita el mismo acto quirúrgico que se realizó para la instalación. El objetivo de este estudio es realizar una revisión bibliográfica de las indicaciones de miniplacas en pacientes con mordidas abiertas, clase II y anomalías de clase III, y buscar cómo las miniplacas han mejorado los tratamientos de ortodoncia. La información principal se reunió buscando en PubMed con las palabras clave enumeradas a continuación. Afirmamos que las miniplacas están indicadas para la retracción en masa de la arcada, donde se observó que la fuerza de 150 g aplicada en los molares superiores es suficiente no solo para empujar los molares hacia atrás en una clase I corregida, sino también para iniciar la retracción de premolares, caninos e incisivos. En pacientes con mordida abierta, las miniplacas se definen como un método seguro, una alternativa rápida y menos costosa a la cirugía ortognática. Y en pacientes de las clases II y III se utilizan sin producir efectos dentoalveolares que sustituyan a los dispositivos extraorales como máscaras, con dispositivos intraorales y elásticos (BAMP).


ABSTRACT: In orthodontics, miniplates are used as a Temporary Anchoring Device (TAD) for the purpose dental movements, allowing the use of orthopedic forces. In comparison with mini-screws, miniplates have the advantage of a very low rate of failure. Nonetheless, their removal requires the same surgical procedure as during installation, which is an obvious disadvantage. The aim of this study is to review the indications of miniplates in patients with open bite, class II and class III anomalies, and review how miniplates improved orthodontics treatments. Information was obtained by a search in PubMed with the keywords listed below. Miniplates are indicated for retraction in mass of the arcade, where it was seen that the force of 150 g applied on maxillary molars, is sufficient not only to push the molars back into a corrected class I, but also to initiate retraction of premolars, canines, and incisors. In open-bite patients, mini plates, are achieved as a safe method, that is quick and a less expensive alternative to orthognathic surgery. Further, in class II and III patients they are used without producing dentoalveolar effects replacing extraoral devices as facemasks, with intraoral devices and elastics. (BAMP).


Subject(s)
Humans , Tooth Movement Techniques/instrumentation , Bone Screws/adverse effects , Dental Implants , Orthodontic Anchorage Procedures/instrumentation , Malocclusion, Angle Class II/surgery , Malocclusion, Angle Class III/surgery , Bone Plates , Cephalometry , Suture Techniques , Suture Anchors , Alveolar Process/surgery , Gingival Retraction Techniques , Molar
14.
China Journal of Orthopaedics and Traumatology ; (12): 1111-1115, 2020.
Article in Chinese | WPRIM | ID: wpr-879364

ABSTRACT

OBJECTIVE@#To evaluate early clinical effects of bioabsorbable suture anchors for the treatment of Bankart lesion.@*METHODS@#Total 23 patients with the Bankart lesion were treated with arthroscopic repair using bioabsorbable suture anchors from January 2010 to June 2017. There were 20 males and 3 females, with an average age of (23.4±3.9) years old (ranged, 19 to 34 years old). Fourteen patients had injuries on the right shoulder joint and 9 patients had the injuries on the left side. The mechanism of primary dislocation included 17 cases of training, 5 cases of sports injury and 1 case of falling down. The mean interval time from injury to surgery was(10.9±5.8) months (ranged, 3 to 36 months). The Bankart lesion was repaired by bio-cortical suture anchors. The Rowes rating system for Bankart repair was used to evaluate therapeutic effects.@*RESULTS@#All 23 patients were followed up, with a mean duration of(24.5±3.7) months(ranged, 18 to 39 months). At the latest follow up, there was no recurrent dislocation occurred, and all patients had returned to sports and work. The Rowes rating system for Bankart repair was 53.91±11.67 pre-operationally and 91.74±12.30 post operationally, respectively (@*CONCLUSION@#Applying bio-cortical bone suture anchors for the Bankart lesion is a reliable, efficient and cost effective treatment, which is also suitable for the revision of the Bankart lesion.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Absorbable Implants , Arthroscopy , Bankart Lesions , Joint Instability , Range of Motion, Articular , Recurrence , Shoulder Dislocation/surgery , Shoulder Joint , Suture Anchors , Treatment Outcome
15.
Rev. bras. ortop ; 54(6): 649-656, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057954

ABSTRACT

Abstract Objective To evaluate the clinical, radiological and functional results of the surgical treatment of acute acromioclavicular dislocation using a coracoclavicular fixation technique (syndesmopexy) with two metallic anchors, temporary clavicle and scapula fixation, and transfer of the coracoacromial ligament. Methods Longitudinal observational study of 30 patients with diagnoses of acute acromioclavicular dislocation, who were submitted to surgical treatment with a minimum follow-up of six months, and who were evaluated clinically, radiologically, and by the University of California at Los Angeles (UCLA), the Disabilities of the Arm, Shoulder and Hand (DASH) and the Constant-Murley functional scores. Results The mean values of the scores were: UCLA = 32; DASH = 11.21; and Constant-Murley = 86.93, with satisfactory results higher than 80%. The unsatisfactory results were associated with acromioclavicular pain on palpation, positive subacromial impingement tests, and older age group, presenting statistical significance (p < 0.05). Radiologically, higher values on account of the coracoclavicular distance ratio from the operated shoulder compared to the normal shoulder were related to worse outcomes, but with no statistically significant difference. No associations were found between the results of the functional scores and the variables degree of the injury, coracoacromial ligament transfer, clinical impression of loss of reduction and scapulothoracic dyskinesis. Conclusion The technique used provides an efficient fixation, with a high level of satisfaction according to the UCLA, Constant-Murley and DASH scores; moreover, it has a low complication rate, despite the high rate of residual radiological acromioclavicular subluxation.


Resumo Objetivo Avaliar os resultados clínicos, radiológicos, e funcionais do tratamento cirúrgico da luxação acromioclavicular aguda, utilizando a técnica de sindesmopexia coracoclavicular com duas âncoras metálicas, fixação temporária clavículo-escapular, e transferência do ligamento coracoacromial. Métodos Estudo observacional longitudinal com trinta pacientes com diagnóstico de luxação acromioclavicular aguda submetidos à cirurgia, com seguimento mínimo de seis meses, avaliados clínica, radiograficamente, e pelos escores de University of California at Los Angeles (UCLA), Disabilities of the Arm, Shoulder and Hand (DASH) e Constant-Murley. Resultados Os valores médios dos escores foram: UCLA = 32; DASH = 11,21; e Constant-Murley = 86,93, com resultados satisfatórios acima de 80%. Os resultados insatisfatórios foram relacionados à dor acromioclavicular, a testes de impacto subacromial positivos, e aos pacientes de faixa etária mais elevada (p < 0,05). Radiologicamente, valores maiores em razão da distância coracoclavicular do ombro operado, comparado com o ombro normal, foram relacionados a piores resultados, embora sem significância estatística. Não foi observada associação entre os resultados dos escores funcionais e as variáveis grau da lesão, transferência do ligamento coracoacromial, impressão clínica de perda de redução, e discinesia escapulo-torácica. Conclusão A técnica utilizada propicia uma fixação eficiente, com alto índice de satisfação segundo os escores de UCLA, Constant-Murley e DASH. Observou-se baixo índice de complicações apesar da frequência elevada de subluxação acromioclavicular radiológica residual.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Wounds and Injuries , Acromioclavicular Joint , Treatment Outcome , Clavicle , Joint Dislocations , Suture Anchors
16.
Journal of the Korean Shoulder and Elbow Society ; : 93-99, 2019.
Article in English | WPRIM | ID: wpr-763620

ABSTRACT

BACKGROUND: Modified Phemister operation has been widely used for the treatment of acute acromioclavicular (AC) joint dislocation. Additionally, the use of suture anchor for coracoclavicular (CC) fixation has been reported to provide CC stability. This study was conducted to evaluate the clinical and radiological results of a modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation. METHODS: Seventy-four patients underwent the modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation and were followed-up for an average of 12.3 months. The visual analogue scale (VAS), range of motion, Constant score, and Korean shoulder scoring system (KSS) were used for clinical assessment. Acromioclavicular interval (ACI), coracoclavicular distance (CCD), and acromioclavicular distance (ACD) were obtained to evaluate the radiological assessments. RESULTS: At the last follow-up, the mean VAS Score was 1.7 points, the mean joint range of the forward flexion was 164.6°, external rotation at the side was 61.2°, and internal rotation to the posterior was a level of T12. The mean Constant score and the mean KSS was 82.7 points and 84.2 points, respectively. At the mean ACI, CCD, and ACD, significant differences were found preoperatively and at the last follow-up. When the ACI, CCD, and ACD were compared with the contralateral unaffected shoulder at the last follow-up, the affected shoulders had significantly higher values. CONCLUSIONS: The modified Phemister operation with CC ligament augmentation using suture anchor is clinically and radiologically effective at acute AC joint dislocation.


Subject(s)
Humans , Acromioclavicular Joint , Joint Dislocations , Follow-Up Studies , Joints , Ligaments , Range of Motion, Articular , Shoulder , Suture Anchors , Sutures
17.
Journal of the Korean Shoulder and Elbow Society ; : 100-105, 2019.
Article in English | WPRIM | ID: wpr-763619

ABSTRACT

Suture anchors are commonly used in shoulder surgeries, especially for rotator cuff tears. Peri-anchor cyst formation, however, is sometimes detected on follow-up radiologic image after surgery. The purpose of this report is to discuss the case of a patient who presented with regression of extensive peri-anchor cyst on postoperative 4-year follow-up magnetic resonance imaging and had good clinical outcome despite peri-anchor cyst formation after arthroscopic rotator cuff repair.


Subject(s)
Humans , Arthroscopy , Follow-Up Studies , Magnetic Resonance Imaging , Rotator Cuff , Shoulder , Suture Anchors , Tears
18.
China Journal of Orthopaedics and Traumatology ; (12): 727-730, 2019.
Article in Chinese | WPRIM | ID: wpr-773846

ABSTRACT

OBJECTIVE@#To explore clinical effects of suture anchor with V-Y tenoplasty for the treatment of old Achilles tendon rupture.@*METHODS@#From May 2014 to March 2018, 26 patients with old Achilles tendon rupture treated by suture anchor with V-Y tenoplasty, including 18 males and 8 females aged from 19 to 56 years old with an average of (36.0±11.7) years old, the courses of disease ranged from 42 to 62 days with an average of (49.0±5.3) days; the distances of Achilles tendon-shortening ranged from 2 to 7 cm with an average of (4.0±1.6) cm. Postoperative complications were observed, preoperative and postoperative American Orthopaedic Foot and Ankle Soviety(AOFAS) score were used to evaluate clinical effects.@*RESULTS@#All patients were followed up from 8 to 18 months with an average of(12.0±2.5) months. No Achilles tendon rupture occurred again. Postoperative AOFAS score at 3 months(93.37 ±3.48) was higher than before operation(57.26±5.06)(t=9.564, <0.05), and 14 patients got excellent results, 11 moderate and 1 poor.@*CONCLUSIONS@#Suture anchor with V-Y tenoplasty for old Achilles tendon rupture could achieve stable fixation, relieve pain, improve walking ability and quality of life, and also recover good function of ankle joint.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Achilles Tendon , Quality of Life , Rupture , Suture Anchors , Suture Techniques , Tendon Injuries , Treatment Outcome
19.
China Journal of Orthopaedics and Traumatology ; (12): 11-16, 2019.
Article in Chinese | WPRIM | ID: wpr-776149

ABSTRACT

OBJECTIVE@#To compare therapeutic effects of single locking plates and locking plates with suture anchors in treating type Neer IIb distal clavicle fractures.@*METHODS@#From January 2013 to January 2015, 40 distal clavicle fractures patients with Neer IIb were treated by retrospectively analyzed and divided into single locking plates (control group) and locking plates with suture anchors(observation group) according to methods of operation. There were 20 patients in control group treated by single locking plates, including 16 males and 4 females aged from 26 to 64 years old with an average of(40.60±12.64) years old; while there were 20 patients in observation group treated by locking plates with suture anchors, including 15 males and 5 females aged from 20 to 57 years old with an average of(37.30±10.56) years old. Length of incisions, operation time, blood loss, hospital stays, fracture healing observed by X-ray, position of internal fixation, and changes of coracoclavicular distance were compared, Constant-Murley score was used to evaluate shoulder joint function.@*RESULTS@#All patients were followed up from 22 to 42 months with an average of (30.08±6.72) months. There was no statistical significance in length of incisions, operation time, blood loss, hospital stays and fracture healing time (>0.05). Constant-Murley score in control group was 83.10±5.81, and lower than that of observation group (92.30±6.05)(<0.05) at final following-up. Coracoclavicular distance in control group (11.22±3.85) mm, was longer than that of observation group (8.71±2.14) mm(<0.05).@*CONCLUSIONS@#Compared with locking plates, locking plates with suture anchors for type Neer IIb distal clavicle fractures has better shoulder joint, shorter coracoclavicular distance. It showed coracoclavicular ligament is an effectiveness method for treating Neer IIb distal clavicle fractures.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Bone Plates , Case-Control Studies , Clavicle , Fracture Fixation, Internal , Fractures, Bone , Therapeutics , Retrospective Studies , Suture Anchors , Treatment Outcome
20.
Archives of Aesthetic Plastic Surgery ; : 52-58, 2019.
Article in English | WPRIM | ID: wpr-762728

ABSTRACT

BACKGROUND: Barbed thread lifting is known to be a minimally invasive procedure compared with standard incisional surgery for facial rejuvenation. However, some studies have pointed out that the effects of thread lifting do not last long and disappear after several months. Therefore, the aim of this study was to evaluate the efficiency and duration of anchoring-type absorbable thread lifting combined with liposuction for facial rejuvenation. METHODS: A retrospective review of 27 cosmetic patients who underwent absorbable barbed thread lifting with liposuction between July 2013 and December 2015 was undertaken. The efficiency of facial rejuvenation was evaluated through a patient satisfaction score and the global aesthetic improvement scale (GAIS). RESULTS: Subjects were divided into two groups: thread lifting only and thread lifting combined with liposuction. The mean follow-up period of each group was 8.5 and 9.3 months, respectively. In the thread lifting-only group, the average patient satisfaction score was 2.36 (1=unsatisfied to 4=very satisfied), and the average GAIS score was 2.54 (1=very much improved to 5=worsen). In the thread lifting with liposuction group, the average patient satisfaction score was 3.06, and the average GAIS score was 1.85. CONCLUSIONS: Thread lifting combined with liposuction showed better patient satisfaction and GAIS results than thread lifting alone, even over a long follow-up period.


Subject(s)
Humans , Follow-Up Studies , Lifting , Lipectomy , Patient Satisfaction , Rejuvenation , Retrospective Studies , Suture Anchors
SELECTION OF CITATIONS
SEARCH DETAIL